25

A/PH

300

V/PH

The HEXAN range test sets are three-phase current and voltage generators controlled manually or by PC with a USB connection. These devices benefit from new DSP technologies and are equipped with direct output amplifiers.  HEXAN is particularly suitable for testing electrical protection relays from the simplest to the most complex, as well as for checking meters and converters.

 
Mô tả chi tiết

Releases

HEXAN is available in two versions:

⇒ HEXAN-C with adjustment controls and integrated display on the front panel and a Flight Case cover.

⇒ HEXAN type II in aluminum casing with crutch handle which favors space and weight.

Fashions

You can control the HEXAN in two modes:

 ⇒ MANUAL, by MCM (integrated or separate), display and manual adjustment of the different electrical quantities (simple, compound voltages, intensities, phases, frequency, etc.) which determine the healthy network and the faulty network. A drop-down menu gives access to the tests: Shunt, recloser, GTE 2666, neutral movement.

 ⇒ CONTROL by PC or tablet , with control software under Windows® Manusof t, offers the user controls by virtual potentiometers with the addition of advanced injection tools, visualization of the Fresnel diagram and symmetrical components.
Light

Accessories

Accessories supplied with the HEXAN

Power cable, USB cable, CD-ROM with Manusoft, user manuals

 

Optional accessories available

Integrated auxiliary power supply 24/48/127 Vdc 30W ref HEX-ALIM
Cable kit ref JC03 including : 18 safety leads 2m 2.5mm², 18 crocodile clips 1 polypropylene carrying case 420 x 210 x 180 mm.
Cords equipped with Essailec® voltage and current plugs (contact us) Nylon carrying
case ref HEX-HOU (HEXAN type II only) Robust waterproof IP54
transport case (HEXAN type II only) with wheels and telescopic handle ref HEX-CAI

Hexan-C

Current (up to 25 A/ph) & Voltage (up to 300 V/ph) User
-friendly operation
Works with integrated controls OR a PC
Portable and robust system 

 

The HEXAN-C takes advantage of the latest component and power integration technologies to offer you a complete three-phase test system in a small footprint. The experience acquired on the HEXAN allows us to integrate a command module available on the front panel. Software control remains possible for complex tests or those requiring more automation. The HEXAN-C is particularly suitable for testing electrical protection relays, as well as for checking meters and converters.
The integrated interface displays and allows you to very easily adjust the three voltages, the three currents, the frequency and the phase shift of the electrical networks generated by the HEXAN. A drop-down menu gives you access to tests of reclosers, decoupling protection, neutral point movement, etc. You have the dual-network function to instantly switch from a healthy network to a faulty network.

 

Software control on PC is carried out by applications from the HEXAN range. Control is carried out by RS232 or USB available on the front panel. The Manusoft software delivered as standard offers the user controls via virtual potentiometers with, in addition, advanced injection tools, visualization of the Fresnel diagram and symmetrical components. The software is compatible with Windows® XP/2000/VISTA/7, 8 and 10 v 32&64 bits.

 

Application software from the HEXAN range

 

AH-PDMI                           Underimpedance protection (railway application)

AH-DDL                             Protection Line fault detector (railway application)

AH-PRODI                         Distance protection

AH-CTF                              Stand-alone source decoupling protection

C15-400 AH-SC                Synchro coupler

AH-MITI                             Current and inverse constant time protection

AH-SMARTEST                  Automatic Relay Test and State Sequencer

AH-PWH                            Zero sequence wattmetric protection

AH-RH7T                          Harmonic generators (15 ranks including 8 to choose from).

 

Manual interface

The control interface now eliminates the need for a PC when using digital cases from the HEXAN-C range. The interface is designed to meet the requirements of users of traditional test cases. Its ease of use, its speed of implementation and its multiple pre-programmed functions give the HEXAN an additional advantage for the systematic testing of protection relays.

 

Main functions of injection control:

Manusoft software functions that simplify testing of protective relays are programmed into the integrated manual control.

  • Control of the 3 voltages and 3 currents of the HEXAN.

Each quantity is controlled by 2 keys: increment and decrement.

Frequency adjustment from 40 to 70 Hz on voltages and currents,

  • Phase shift of voltages relative to currents  from –180° to +180° or 0 to 360°
  • Dual network management : healthy and faulty networks,
  • Direct or stepwise injection mode ,
  • Simultaneous variation of the 3 voltages and 3 currents by locking the controls,
  • Movement of the neutral point following V1, V2 or V3,
  • Variation of compound voltages : U12, U23, U13,
  • Current differential mode,
  • Vector jump,
  • Recloser testing

 

Digital chronometer and injection control part:

Large graphic display on backlit LCD screen giving an overview of injection parameters.

Stopwatch resolution: 1ms

Measuring range: 0-199.999 s

Start of the stopwatch on injection or external event

Cycle measurements (recloser example) 4 independent timer inputs configurable in contact or voltage.

 

Resolution of adjustable quantities:

  • 100mV, 10mA, 10mHz, 0.1°

 

Manusoft Software

MANUSOFT is aimed at all users, because it allows you to test protection relays from the simplest to the most complex with unrivaled user-friendliness. It only takes a few minutes to get started. It is an easy-to-use manual interface that allows you to quickly test your protections. You access all possible settings with just a few mouse movements and a few “clicks”.

 

The different electrical quantities are controlled either from virtual potentiometers, or using the mouse by moving the vectors in the FRESNEL diagram or by entering the values ​​on the keyboard. Numerous tools help the user to carry out the tests: Visualization and calculation of symmetrical components, 2 or 4-channel stopwatch with display of times and chronograms, display of inter-channel times, balanced networks and tools for creating two-phase and zero-sequence faults , 8 memories for storing faults to be produced.

The tests carried out can be saved in the form of files, allowing the provision of test reports.

 

Uses

Search for trigger threshold and measurement of reaction time of type protections:

  • Amperometric
  • Voltmetric
  • Wattmetric (single and three phase)

Realizations of defects:

  • Single phase
  • Two-phase
  • Three-phase
  • Simple or recurring (Recloser test)

 

The precision and stability of the injection make it possible to measure the characteristics of the measurement transducers.

 

hexan

 

Adjust your networks very easily, using the mouse for large adjustments, using the keyboard arrows for finer adjustments. You can even enter the numerical value directly from the keyboard!

 

Easily lock your generators for simultaneous variation…

Features

Amplifiers

All amplifiers are temperature and overload protected.
The grounds of the voltage amplifiers are common and connected to earth.

 

Voltage
Amplifiers           13 V/130 V for model 6X0
3x Ph-N                       3x 0…130V
1x Ph-Ph                     1x 0…260 V
Power:                 3x 60 VA at 130 V
Resolution:                400 µV at 13V; 4 mV to 130 V
Accuracy:                   0.1%
Distortion:                 0.1% THD*

 

130 V/260 V amplifiers           for model 6X1
3x Ph-N                       3x 0…260 V
1x Ph-Ph                     1x 0…520 V
Power:                 3x 60 VA at 260 V
Resolution:                4 mV at 130 V; 8 mV to 260 V
Accuracy:                   0.1%
Distortion:                 0.1% THD*

 

150 V/300 V amplifiers          for model 6X2
3x Ph-N                      3x 0…300 V
1x Ph-Ph                    1x 0…600 V
Power:                3x 70 VA at 300 V
Resolution:                5 mV at 150 V; 9 mV to 300 V
Accuracy:                  0.1%
Distortion:                 0.1% THD*

 

Current
Amplifiers          15 A 40 VA for model 60X
3x Ph-N                      3x 0…15 A
1x Ph-Ph                    1x 0…45 A
Power:                3x 40 VA at 15 A
Resolution:              460 µA
Accuracy:                   0.1%
Distortion:                 0.1% THD*

 

Amplifiers          15 A 110 VA for model 65X
3x Ph-N                      3x 0…15 A
1x Ph-Ph                     1x 0…45 A
Power:                3x 110 VA at 15 A
Resolution:               460 µA
Precision:                   0.1%
Distortion:                 0.1% THD*

 

Amplifiers          5A / 25 A 175 VA for model 61X
3x Ph-N                      3x 0…25 A
1x Ph-Ph                    1x 0…75 A
Power:                3x 175 VA at 25 A
Resolution:              150µA at 5A; 760 µA at 25A
Accuracy:                   0.1%
Distortion:                 0.1% THD*

 

*THD: values ​​at full load (100% of range) and at 45-65 Hz

 

EMC

The product complies with Directive 2004/108/EC on electromagnetic compatibility

 

Security

The product complies with directive 2006/95/EC and in particular NF EN 61010-1

 

Environmental Conditions

Operating temperature: 0°C—50°C Storage temperature: -25°C—+70°C Relative humidity: 5 to 95% non-condensing Pollution degree 2; installation category II

 

Software Suite

Compatible with Windows® 2000/XP/VISTA/7, 8, 10 v32&64 bits USB
connection (native without converter) or  RS232

 

Housing

HEXAN Type II

Type: aluminum box with carrying handle Dimensions: L=448, D=320, H=180.5 mm
Weight: 13 kg

 

HEXAN-C

Type: Flight Case
Dimension: L=420, W=350, H=480 mm Weight: 24 kg

 

Food

180-264 Vac, 50/60 Hz
90-132/180-264 Vac, 47 to 63 Hz (option) Power: 900 VA Maximum
2100 VA Maximum for 25 A models
Connection: IEC 320 plug

 

Stopwatch Inputs

Number: 4
Insulation: All channels are isolated
Signal type: Signals in contact with floating potential or AC/DC voltage up to 250V
Connection: 4 mm safety sockets.
Accuracy: 0.02% of the value +-1 ms Resolution: 1 ms

 

Configurable Logic Outputs

Number: 3
Signal type: Dry contact (NO/NC)
Connection: 4 mm safety sockets.

 

Frequency

Range: 0.1…500 Hz
Resolution: 500 µHz Accuracy: ± 1 mHz to 50 Hz