Chi Tiết Sản Phẩm

NanoBrook 173

Features at a glance

 

  • Rapid and accurate protein and nanoparticle size distributions
  • Multimodal & unimodal size distribution software
  • ISO 13321 and ISO 22412 compliant results
  • Range > 0.3 nm to 10 µm
  • Customizable reports
  • Ideal for fast, routine sizing applications in research or quality control
  • High power 35 mW diode laser
  • Dynamic light scattering at 173° only
  • Temperature control, -5 °C to 110 °C
  • Compact bench top unit, USB connection
  • Brookhaven's NanoBrook 173 instrument is the go-to-solution for characterization of proteins, antibodies, nanoparticles, macromolecular assemblies and other molecules/particles of small sizes.  The NanoBrook 173 uses backscattering detection for the highest sensitivity and accuracy optimized for molecules and particles less than a few tens of nanometers.

    Reliable, Accurate, and Accurate Analysis

    The new NanoBrook 173 protein and particle size analyzer incorporates all you need for fast, routine, sub-micron measurements. Based on the principles of Dynamic Light Scattering (DLS) for particle sizing and distribution, most measurements only take a minute or two.

    Nanoparticles

    Dilute suspensions, on the order of 0.0001 to 1.0% v/v are prepared, using suitable wetting and/or dispersing agents, if required. A small ultrasonicator is sometimes useful in breaking up loosely-held agglomerates. Sample volumes as small as 50 µL are used. Sample is recoverable. Disposable, polystyrene U-shaped cells are used for aqueous and simple alcohol suspensions. Just a few minutes are required for the sample and cell to equilibrate with the actively controlled temperature environment inside the NanoBrook 173.

    Speed and low concentration/small size capabilities

    The NanoBrook 173 utilizes backscattering to size the proteins/particles by accumulating the correlation function. The smoother the function, the better the results are. For small molecules, the scattered intensity is typically low. The measurement takes longer to get enough statistics from the photons counted to aquire a good results. The backscattering angle makes for a larger scattering volume, measuring more proteins/particles for a quick measurement of their sizes. The advantage of the backscattering is clear for sizes below 10 nm.

    Data Presentation

    The NanoBrook 173 protein and particle size analyzer offers many choices for data analysis. One choice is the lognormal distribution by: intensity, volume, surface and number. Another choice, the full size distribution (MSD) can be displayed by the same four weighting factors. In the example above, the MSD is presented by volume for lysozyme. The size distribution and cumulative distribution are shown in the table on the right. Lysozyme has a very low polydispersity in this case.

     

    Specification

    Sample Type Most globular proteins, nanoparticles, and small polymers in any non-absorbing liquid
    Size Range > 0.3 nm to 10 µm diameter, depending on refractive index and concentration
    Sample Cells 50 µL disposable, 1 to 3 mL disposable plastic, glass or quartz cells
    Concentration Range 0.1 ppm to 50 mg/mL, depending on refractive index and concentration
    Signal Processing Dynamic Light Scattering, DLS
    Correlator Brookhaven's TurboCorr, multitau research grade with 510 hardware channels, covering the equivalent of 1010 linearly-spaced channels, 100% efficiency, real-time operation over the entire delay-time range
    Precision ± 1% typically 
    Temperature Control -5 °C to 110 °C, ± 0.1 °C, active control. No external circulator required.
    Condensation Control Purge facility using dry air, nitrogen preferred
    Standard Laser 35 mW red diode laser, nominal 640 nm wavelength
    Scattering Angle 173°
    Data Presentation Average & width, lognormal fit, and multimodal size distribution standard
    Compliance ISO 13321 and ISO 22412 compliant results
    Power Requirements 100/115/220/240 VAC, 50/60 Hz, 150 Watts
    Dimensions 23.3 x 42.7 x 48.1 (HWD)
    Weight 15 kg
    Environmental Characterisitics

    Temperature 10 °C to 75 °C

    Humidity 0% to 95%, non-condensing

    CE Certificate Class I laser product, EN 60825-1:2001 CDRH

    Tin tức & Sự kiện